Features
- Backlight on-board LCD display
- Monitor and control power switches
- Optional MODBUS RTU communications
- Optional digital and analog I/O
- Optional relay outpu
- Optional data logging
- Get optional alarm notification
- Standard DIN size for easy installation
Applications
- DC Energy Management Systems
- Power Distribution for Telecommunication Room
- Solar Photovoltaic Systems
- Industrial DC Control Systems
- Metallurgy and Electroplating Industries
- Wind Power Generation
|
- DC Excitation Systems
- Light Rail Transit Systems
- EV Charging Monitoring
- Data Center
- Cellular Tower Energy Monitoring
|
Description
AcuDC 240 Series specialty DC energy meters for monitoring solar PV energy generation, wind turbine power generation, transport systems, cell towers, power distribution in data centers, IT networks and other DC applications.
Model: Acuvim 240 Power Meters |
Real Time Metering |
Voltage: |
V |
Current: |
I |
Power: |
P |
Energy: |
E |
Ampere-hour: |
Ah |
|
Accuracy |
Resolution and Range |
Voltage: |
0.2% |
0.001V (0~1200V) |
Current: |
0.2% |
0.001A (0~±50000AA) |
Power: |
0.5% |
0.001kW (0~±60000kW) |
Energy |
0.5% |
0.01kWh (0~9999999.99kWh) |
Drift withTemperature: |
<100ppm/˚C |
Stability: |
0.5‰/year |
Inputs |
Current |
Input Range: |
0~±10A (Direct Input, pick up current 0.01A)
0~±50000A (Via Shunt or Hall Effect Sensor, 50~100mV(programmable |
Shunt: |
50~100mV(programmable) |
Hall Effect Sensor: |
0~±5V/0-±4V, 4~20mA/12mA±8mA |
Power Consumption: |
2W(Max) |
Accuracy |
0.2% |
Voltage |
Input Range: |
Direct Input0~1000V; Via Hall Effect Sensor0~1200V |
Input Impedence: |
2MΩ |
Load: |
<0.6W |
Accuracy |
2MΩ /phase |
Digital Inputs |
Type: |
Dry Contact |
Isolation Voltage: |
0.2% |
Outputs |
RO Outputs (Optional) |
Type: |
Mechanical contact, Form A |
Max Load Voltage: |
3A |
Max Load Current: |
250Vac/30Vdc |
On Resistance: |
100mΩ (Max) |
Isolation Voltage: |
4000Vac |
Mechanical Life: |
5 × 106 times |
Digital Output (Photo-Mos) |
Load Voltage Range: |
0~250Vac/dc |
Load Current: |
100mA (Max) |
Max Output Frequency: |
25Hz, 50% Duty Ratio |
Isolation Voltage: |
2500Vac |
Analog Output (AO) |
Output Range: |
4~20mA/0~20mA;0~5V/1~5V |
Accuracy: |
0.5% |
Load Capacity: |
Current Type: Max Resistance 500Ohm
Voltage Type: Max Output Current 20mA |
Communication (Optional) |
Type: |
RS485, half duplex, Optical Isolated |
Protocol: |
Modbus-RTU |
Baud Rate: |
1200~38400bps |
Isolation Voltage; |
2500Vac |
Specifications |
Power Voltage: |
(P1)100-240Vac, 50/60Hz, 100-300Vdc
(P2) 20-60Vdc |
Power: |
3W |
Temperature Range: |
-25⁰C~70⁰C |
Storage Temperature: |
– 40°C to 85°C |
Humidity Range: |
5% to 95% Non-Condensing |
Dimensions: |
72x72x64.5 mm – Panel Cutout 68×68mm |
|
◎- OPTIONAL |
Acuvim |
|
Parameter |
AcuDC 241 |
AcuDC 242 |
AcuDC 243 |
Real Time Metering: |
Voltage |
● |
|
● |
Current |
|
● |
● |
Power |
|
|
● |
Energy: |
|
|
● |
Ampere-hour: |
|
|
● |
|
I/O Functions: |
2DI+2AO |
◎ |
◎ |
◎ |
2DI+2RO |
◎ |
◎ |
◎ |
2DI+2DO |
◎ |
◎ |
◎ |
2DI+ ±15Vdc |
◎ |
◎ |
◎ |
Data Logging: |
All metering parameters can be recorded |
|
|
◎ |
Communication: |
RS485 |
◎ |
◎ |
◎ |
|