Accuenergy DC Current Shunts
- 0.5% accuracy
- 50A to 6000A measurement range
- 75mV rated voltage output
AcuCT 5A – Split Core Current Transformers
- 0.5% accuracy from 10%-120% of rated current
- 100A to 6000A measurement range
- Industrial standard 5A secondary output
- Optional 1A output
- Accessory kits included for mounting in multiple locations
- UL recognized
AcuCT Flex – Flexible Current Transformers
- High accuracy for demanding applications
- Wide frequency range means excellent choice for harmonics and power quality
- Wide current input range from 5A – 50,000A AC
- Choice of 16″, 24″, 36″ or 47″ length
- No additional power supply needed when used with Acuvim II Series meters
- Fully customizable selection of flexible CT
AcuCT Hinged – Split Core Current Transformers
- Quick & simple install with hinged clip
- Safe mV secondary output
- 5A – 630A AC current input range
- 0.5% accuracy from 10-120% of rated current
- UL recognized
AcuCT mV – Split Core Current Transformers
- Conventional 333 mV split-core CT
- Safe mV secondary output
- 0.5% accuracy from 10-120% of rated current
- 20A – 5000A AC current input range
- UL recognized
AcuCT R – Split Core Current Transformer
- 5A – 5000A AC current input range
- Revenue grade accuracy meets IEC61000-1 class 0.5
- UL listed for XOBA UL2808 standard, CSA C22.2 No. 61010-1
- Push-open mechanism makes the installation quick and simple
- Multiple voltage or current secondary output options including 5A and 333mVMultiple mounting options with included accessories
- Multiple window shapes and sizes for multiple applications
AcuCT S113 – Solid Core Current Transformers
- 1% Class Accuracy
- 1.2In RF
- 50Hz-60Hz Rated Frequency
- ≤±1.0% Ratio Error
- ≤60´ Phase Error
- 5-120% Measurement Range
- 500V / 100 MΩ min insulation resistance
AcuCT S77 – Solid Core Current Transformers
- 0.15 class accuracy
- 10 kV impulse insulation (BIL)
- 50 MΩ insulation resistance
- 18 AWG UL 1015 Lead Wire
- Measurement Canada Approved
AcuDC 240 Series – DC Power Meters
- Backlight on-board LCD display
- Optional MODBUS RTU communications
- Optional digital and analog I/O
- Optional relay output
- Optional data logging
- Get optional alarm notification
- Standard DIN size for easy installation
AcuLink 710 – Data Acquisition Server
- Connect field-deployed devices to servers and log/present information
- Accesses device data from remote sites
- View real-time performance across multiple sites and devices
- Monitor renewable energy performance and production
- Monitor performance of critical systems such as lighting, HVAC, PDUs, inverters, etc
- Track energy use and peak demand
- Threshold alarm notification
- Great for measurement and verification (M&V) LEED/ Energy start certification
AcuLink 810 – Data Acquisition Server & Gateway
- Ethernet gateway for Modbus RS485 and digital output devices
- Access energy information remotely via web server, or push to IP-based master devices or software
- Data acquisition and logging with 8GB on-board memory
- Embedded webserver for real-time data and easy configurations
- Controller/Master system can poll data from all RTU devices via Modbus-TCP/IP Protocol
- Dual ethernet RJ45 port and WiFi communication channels
- Enhanced cybersecurity for critical infrastructure deployment
- Compact DIN rail mount design
- Track energy usage and peak demand
- Quick and simple software-free setup
AcuMesh – Wireless RS485 Network
- Available in both 900MHz and 868MHz frequency
- Automatic connection without any configuration or software
- Compatible with any protocols: Wireless Modbus RTU, Profibus, DNP 3.0 and more
- Highly secure 128-bit Advanced Encryption Standard (AES)
- Advance configuration available for complex network setup with free software
- 1000 ft (305m) indoor / 4 Miles (6.5km) outdoor in a single hop
- Each transceiver acts as an extension point for the network allowing for a longer range of communication
- Point to multi-point communication enabled with “mesh” structure
- Self-healing and optimizing communication pathway