GXR Series

Dylix Corporation ® GXR Series

General Process Hardened Transmitters

spacer

Dylix GXO Series, Pressure Transmitters

spacer

Characteristics:

  • 0-3 psi through 0-15,000 psi
  • Hermetically Sealed Package
  • ±0.25% FSO Static Accuracy
  • 0-3 psi through 0-20,000 psi
  • Possible Switch
    Replacement
  • Low Cost
  • ±0.1% FSO Static Accuracy
  • ±0.5% FSO Thermal Error Band
  • Hasteloy or Inconel alt. materials
  • Low power

space
Product Description:

 

Designed for hazardous locations
Senex’s GXR Series Pressure Transmitter is designed for use in
hazardous locations. The GXR’s entirely welded 316LSST
construction is hermetically sealed, and Factory Mutual and
Canadian Standards Association Explosion Proof certification are
pending.

Manufactured for reliable service in aggressive environments
The GXR is manufactured for reliability in aggressive environments
where other transmitters fail. Senex’s automated weld procedures,
extreme environmental burn in, and the mounting of our electronics
to withstand the most severe shock and vibration applications are all
geared toward safety and reliability. Additional EMI/RFI filtering with
surge protection add to the performance of the GXR.

Alternate materials for service in corrosive environments
For corrosive environments where 316L or 15-5 SST are not best
suited, the GXR is available in Hasteloy C276, C22 or Inconel 718.

General Specifications :

space
Electrical
Excitation
GXR1
GXR2 & GXR3
2-15 Vdc
8-38 Vdc*
Output
GXR
GXR2
GXR3
1-2 mV/V*
0-5 Vdc*
4-20 mAdc
Zero Balance :
±1% FSO
FSO Setting :
±1% FSO
Resolution:
Infinite (±.001% FSO usable)
Response Time:
GXR1
GXR2 & GXR3
< 1mS
< 5 mS
Insulation Resistance:
1000 MO @ 50 Vdc
Reverse Polarity:
Protected
Warm up : < 10 mS
Power Supply Effect:
±.002% FSO per V input (GXR2 & GXR3)
EMI/RFI:
Internal Filtering (GXR2 & GXR3)
Short Circuit :
Protected Up to 40 Vdc (GXR2 & GXR3)
Performance
Static Accuracy:
±0.25% FSO* (BFSL, RSS)
(combined effects of non-linearity, hysteresis &repeatability)
Repeatability :
±0.05% FSO
Temperature Effects :
±1.5 % FSO over comp range
(combined effects of Zero & FSO with reference at 70 oF)
Long Term Stabily:
±0.25 % FSO per year
Environmental
Compensated Temp Range:
0 to 170 °F
Operating Temp Range:
-40 to 200 °F
Storage Temp Range:
-40 to 225 °F
Mechanical
Pressure Ranges:
0-3 through 0-20k psi
(Customer may specify any range/eng. unit FOC)
(Absolute, vacuum, compound available options)
Line Pressure:
2X Full Scale
Burst Pressure:
5X Full Scale
Materials:
Wetted
Non-wetted Parts:
Parts 316L SST*
316L SST plus electrical connector
Pressure Port:
¼”-NPT Female
Electrical Connector :
NEMA 4X cable exit (24” cable)*
Weight:
nominal 15 oz
space

pdf_pic General Specifications

space
base
spacespace
index web