Model: M300 Data Acquisition/ Switch System |
Display Resolution: |
480 x 272 TFT LCD |
Size: |
4.3” |
DC Characteristic |
DC Voltage |
Input Impedance: |
200mV, 2V, 20V ranges: 10MΩ or >10GΩ
(For these ranges, input beyond ±26 V are clamped through 106 kΩ) |
200V and 300V ranges: 10MΩ±1% |
Input Protection: |
300V |
Input Offset Current: |
50pA, at 25℃, typical |
CMRR: |
140 dB for 1 kΩ unbalanced resistance in LO lead, ±300 VDC peak maximum. |
Resistance |
Measurement Method; |
4-wire or 2-wire resistance
Current source referenced to LO input |
Open-circuit Voltage: |
Limited to <10 V |
Max. Lead Resistance
(4-wire): |
10% of range per lead for 200 Ω and 2 kΩ ranges, 1 kΩ per lead on all other ranges |
Input Protection: |
300V on all ranges |
Offset Compensation: |
Available on 200 Ω, 2 kΩ and 20 kΩ ranges. |
DC Current |
Shunt Resistor: |
100 Ω for 200 uA, 2 mA
1 Ω for 20 mA , 200 mA
0.01 Ω for 2 A, 10 A |
AC Characteristics |
True RMS AC Voltage |
Measurement Method: |
AC-coupled True-RMS — measure the ac component of input with up to 300 V DC bias on any range. |
Crest Factor: |
≤ 5 at full range |
Input Impedance: |
1 MΩ ± 2%, in parallel with <150 pF capacitance on any range |
Input Protection: |
300 V rms on all ranges |
AC Filter Bandwidth: |
Slow: 3 Hz – 300 kHz
Medium: 20 Hz – 300 kHz
Fast: 200 Hz – 300 kHz |
CMRR: |
70 dB, for the 1 kΩ unbalance in LO lead, <60 Hz common mode signal frequency, ±500 VDC peak maximum |
True RMS AC Current |
Measurement Method: |
Direct coupled to the fuse and shunt; AC-coupled True RMS measurement (measure the AC component). |
Crest Factor: |
≤ 3 at full range |
Max. Input: |
DC + AC current peak value <300% of range. Current with DC current component <10 A rms. |
Shunt Resistor: |
100 Ω for 200 uA, 2 mA
1 Ω for 20 mA , 200 mA
0.01 Ω for 1 A |
Frequency and Period Characteristics |
Frequency and Period |
Conversion: |
Reciprocal-counting technique, AC-coupled input using the AC voltage function |
Input Impedance: |
1 MΩ ± 2%, in parallel with <150 pF capacitance on any range |
Input Protection: |
300 Vrms on all ranges |
Temperature Characteristics |
Thermocouple |
Conversion |
ITS-90 software compensation |
Reference Junction Type: |
Internal, Fixed, or External |
T/C Check |
Selectable per channel. When the channel resistance is >5kΩ, it is considered as Open. |
RTD |
Alpha: |
= 0.00385 (DIN/IEC 751): using ITS-90 software compensation;
= 0.00389, 0.00391 or 0.00392: using IPTS-68 software compensation |
Thermistor |
Series: |
44004, 44007, 44006 |
General |
Digital Input/Output (DIO) |
Port 1,2,3,4: |
8-bit, input or output, non-isolated |
Type: |
Vin(L) |
Vin(H) |
Vout(L) |
Vout(H) |
Vin(H) |
<0.8V |
>2.0V |
<0.2V@Iout=-500mA |
>4.8V@Iout=1mA |
<42V with external open drain pull-up |
<1.5V |
>3.5V |
<0.2V@Iout=-500mA |
>4.8V@Iout=1mA |
<1.0V |
>2.3V |
<0.2V@Iout=-500mA |
>3.15V@Iout=1mA |
<0.75V |
>1.75V |
<0.2V@Iout=-500mA |
>2.35V@Iout=1mA |
Threshold
-0.3V |
Threshold
+0.3V |
<0.2V@Iout=-500mA |
>(Level-0.2V)@Iout=1mA |
T/C Check |
Selectable per channel. When the channel resistance is >5kΩ, it is considered as Open. |
Specifications |
Power Voltage: |
AC 100V – 120V, 45Hz – 440Hz
AC 200V – 240V, 45Hz – 66Hz
Detect the power frequency automatically at power-on, 400 Hz defaults to 50 Hz |
Power Consumption: |
25 VA Max |
Temperature Range: |
Full accuracy for 0℃ to 50℃
Full accuracy to 80% R.H. at 40℃ Non-coagulation |
Storage Temperature: |
-40℃ to 70℃ |
Humidity Range: |
0℃ to 30℃ ≤95% rel. humidity
30℃ to 40℃ ≤75% rel. humidity |
Storage: |
Flash non-volatile memory (internal); USB disk (not supplied)
Flash non-volatile memory (internal) 1G Bytes |
Remote Interface: |
GPIB, 10/100Mbit LAN, USB 2.0 Full Speed Device & Host (support USB storage device), RS-232 |
LXI: |
LXI Core Device 2011,Version 1.4 |
Dimensions: |
159.0mm × 239.0mm × 373.4mm |
Weight: |
About 5.7 kg (without package) |
Safety: |
IEC 61010-1; EN 61010-1; UL 61010-1; CAN/CSA-C22.2 No. 61010-1
Measurement CAT I 1000V/CAT II 300V
Pollution Degree 2
EN 61326-1 |