Features
- 2 Outputs; 60V/1A & 8V/10A Remote Sensing, total power up to 140W
- Low Ripple Noise <350 uVrms/2mVpp
- Fast transient response time: <50 us
- Up to 10A and 60 V
- OVP/OCP/OTP protection functions
- Built in V, A, W measurements and waveform display
- Support for output Delay, Analysis, Monitor, and Preset functions
- Connectivity including USB Host & Device, LAN, and Digital IO
-
IIII [+] Read More
- 3.5 Inch TFT Display
- Standard Timing function
- Independent control for each channel
Applications
- R&D Iab General purpose testing
- Educational Applications
|
- Research and Development
- Bench use
|
Description
The DP821A has two outputs 60V/1A and 8V/10A with Remote Sensing and total power of up to 140W. Source flexibility allows users to reconfigure the DP821A be used in many systems or applications. Built in V, A, and W measurements make power monitoring easy, but additional wave tracking, timing, and analysis features allow for greater application flexibility. New digital triggering between instruments also makes it possible to reliably combine and connect supplies together. Intuitive to use, the DP821A is ideal for educational applications, lab, R & D and bench use.
- Literature
- Specifications
Model: DP821A Programmable Power Supplies |
Display: |
3.5 Inch TFT Display |
Display Modes: |
Dual display, multiple parameters and state graph simultaneously |
Channels: |
2 |
Load Regulation ± (output percentage + offset) |
Voltage: |
<0.01%+2mV |
Current: |
<0.01%+250uA |
Linear Regulation ± (output percentage + offset) |
Voltage: |
< 0.01% + 2 mV |
Current: |
<0.01%+250uA |
Ripple and Noise (20 Hz – 20 MHz) |
Normal Mode Voltage: |
<350μVrms/2mVpp |
Normal Mode Current: |
< 2 mA rms |
Temperature Coefficient per ℃ (output percentage + offset) |
Voltage: |
0.01%+3mV |
Current: |
0.02%+3mA |
Stability, ±(output percentage + offset) |
Voltage: |
0.02% + 1mV |
Current: |
0.1% + 1mA |
OVP/OCP |
Accuracy: |
.5%+0.5V/0.5%+0.5A |
Activation Time: |
1.5ms(OVP≥ 3V)
<10ms(OVP<3V和OCP) |
DC Output ( 0℃ – 40℃) |
|
CH1: 8V/10A |
CH2: 60V/1A |
Voltage:
Current:
OVP:
OCP: |
0~+8V
0~10A
0.1V~8.8V
0.1A~10.5A |
0~+60V
0~1A
0.1V~66V
0.1A~1.1A |
Resolution |
Programming |
Voltage: |
1mV |
Current: |
CH1:0.3mA
CH2/CH3:0.1mA |
Read Back |
Voltage: |
0.1mV |
Current: |
0.1mA |
Display |
Voltage: |
1mV |
Current: |
1mA |
Accuracy 12 Months (25℃±5℃) ±(output percentage + offset) |
Programming |
Voltage: |
8V/10A:<0.05%+10mV
60V/1A:<0.1%+25mV |
Current: |
0.2%+10mA |
Read Back |
Voltage: |
8V/10A:0.05%+5mV
60V/1A:<0.1%+25mV |
Current: |
0.15%+10mA |
Voltage Programming Control Speed (1% within the total variation range) |
Rising |
Full Load: |
CH1:<92ms
CH2:<11ms |
No Load: |
CH1:<30ms
CH2:<15ms |
Falling |
Full Load: |
CH1:<90ms
CH2:<17ms |
No Load: |
CH1:<486ms
CH2:<154ms |
Specifications |
Power Voltage: |
100Vac+10%,115Vac+10%
230Vac+10%(maximum 250VAC) |
Temperature Range: |
Full rated value output: 0℃ – 40℃
Under Relatively Higher Temperature: the linearity of the output current reducesdecreases linearly to 50% at the highest temperature 55℃ |
Interface Ports: |
GPIB, LXI-C (Ethernet), USB host & device interfaces all standard |
Dimensions: |
239mm(W) x 157mm(H) x 418mm(D) |
Weight: |
110kg |
|