• RISHABH

Rish CON-P Power Transducer Series

Digital Utility Power Transducer for Power Management Applications
Rishabh Rish CON-P Digital Power Transducer series

Features

  • True RMS measurement
  • On-site programmable input voltage & current range
  • On-site selectable output type (dc voltage/ dc current)
  • Single or dual output
  • Accuracy class 0.2 (IEC/EN 60688) for Power
  • Accuracy class 0.5 (IEC/EN 60688) for Phase Angle/Power Factor
  • 7 segment LCD display
  • RS-485 (Mobus) Communications
  • Wide auxiliary power supply (60V-300V) AC & DC
  • Output Response time <75 ms
  • DIN rail installation
IIII [+] Read More
  • Measuring input: AC Voltage/Current, sine wave or distorted waveform
  • Analog output (single or dual) – isolated analog output programmable on-site (voltage or current)
  • Programmable input/output
  • RS-485 communication
  • LED indication: Power on and output type
    Current output: Red LED
    voltage output: green LED

Applications

  • Generation and Industrial applications – measuring power quantities and providing a proportional (real-time) analog signal
  • Power/Energy & Load monitoring
  • OEM Applications

Description

The Rish CON-P programmable transducer series measure and convert active, reactive and apparent power of a single-phase or three-phase AC system with balanced or unbalanced loads. The output signal is proportional to the measured value of the active or reactive power and is either load-independent DC Voltage or DC Current output signal. The CON-P transducer is field programmable and/or data can be retrieved via optional 7 segment LCD display with backlit keypad or connecting a PC with RS232 interface and PRKAB601 adapter connected to the CON-P’s front panel programming connector, or simply networked via the RS485 port.

IIII [+] Read More

The Rish CON-P transducer series is available with an optional LCDprecision engineered to provide superior accuracy , reliability and manufactured from finest materials and components for long-term performance.

  • Literature
  • Specifications

Literature and Technical Information

pdf icon

Signal Modifiers

++ RISH CON-P Series -Power/Phase Angle/Power Factor Transducer
Model: Rishabh RIS CON-P Power transducer
Measured parameters
Power Measurement: Active, reactive and apparent power
Phase angle
Power factor
Specific Accuracies
Power: ±0.2% accuracy
Phase Angle: ±0.5% accuracy
Power Factor: ±0.5% accuracy
Network type supported
Power Transducer: Single phase
3phase 3 wire
unbalanced
3phase 4 wire
unbalanced
3phase 3 wire
balanced
3phase 4 wire
balanced
Ø Angle, Power Factor: Single phase
(U12 I1) 3phase balanced load
(U13 I1) 3phase balanced load
(U23 I1) 3phase balanced load
3phase 3 wire
balanced load
3phase 4 wire
balanced load
Nominal Voltage Input
Nominal input Voltage
PT Secondary range
100 V ≤ UN ≤ 500 VL-L
PT Primary range: 100 V ≤ 692 KVL-L
Nominal Frequency (FN) 25 Hz to 65 Hz
Nominal input Voltage Burden: < 0.6VA per phase at UN
Overload Capacity: 1.2 UN continuously
X2 UN for 1 seconds, repeated 10 times in a 10 minute interval
(UN maximum with power supply powered for measuring input)
Nominal Current Input
Nominal input Voltage (AC RMS)
PT Secondary range
1 A ≤ IN ≤ 5 IN
PT Primary range: 1 A – 9999 A
Nominal Frequency (FN) 25 Hz to 65 Hz
Nominal input Voltage Burden: < 0.2VA per phase at IN
Overload Capacity: X1.2 current continuously
X10 current for 3 seconds, repeated 5 times in a 5 minute interval
X50 current for 1 seconds, repeated 1 times in a 1 hour interval
Phase Angle and Power Factor Measuring Angle
Range: Minimum range: 20° to Maximum range: 360°
Output Type: Load independent DC Voltage, DC Current (on-site dip-switch selectable)
Low independent DC output: Unipolar: 0…20mA, 4…20mA or 0…10V
Bipolar: -20mA…0..+.20mA, 4…20mA or -10…0…+10V
Output Burden – DC Current output: 0 ≤ R ≤ 15 V/Y2
Output Burden – DC Voltage output: Y2 (2mA) ≤ R ≤ ∞
General Specifications
Protection Class: II (Protection isolation, EN 61010)
Case rating: IP40 housing, EN 60 529
IP20 terminals EN 60 529
Case Materials: Lexan 940 (polycarbonate)
Flammability class: UL 94 self extinguishing
Insulation Category: 50Hz, 1 minute (EN 61010-1)
5500V input versus outer surface
3700V input versus all other circuits
3700V auxiliary power supply versus outer surface and output
Mounting: Rail Mounting, wall mounting
Weight: approx. 04kg
Environmental
Operating Temp.: 0 to 23°C to 45°C
Storage Temp: -40°C to 70°C
Relative Humidity: ≤ 75% (non condensing)
Frequency Range: 10Hz …150Hz …10Hz
Ambient Tests: EN 60 068-2-6 (Vibration), EN 60 068-2-7 (Shock), EN 055 011[IEC 1000-4-2/-3/-4-6] Electro-magnetic compatibility, EN 60 068-2-1/-2/-3 cold, dry, damp heat