Yokogawa AQ7260 Fiber Optical Time Domain Reflectometer

Yokogawa  AQ7260 Optical Time Domain Reflectometer

Characteristics:

  • Sampling resolution : min. 5cm
  • Sampling points : max. 60,000
  • 8.4 inch TFT-LCD color display for easy viewing
  • Large internal memory : 20MB
  • USB ports for connectivity and data storage
  • Telcordia GR 196 file format for data storage
  • Compact and light weight : approx. 3kg
  • A variety of optical modules
  • Speed, Ease-of-use
  • Increased Efficiency of Optical
    Network Testing

Applications:

  • Installing, commissioning and documenting fiber optic networks
  • Maximize Network Performance (system tune-up)
  • Maintain and Diagnose Networks
  • Restoration applications

Product Description:

space
space

The AQ7260 OTDR covers a wide range of applications
from installation and servicing of optical networks. This flexible OTDR is available with a variety of OTDR modules and optional units.

The AQ7260 provides the complete test and measurement solution for optical Networks. It can be configured to meet the most demanding requirements from fault location to pinpointing and addressing light loss points.

General Information:

space
|||||||| Click here for Features and Functions

Simultaneous Display of Trace and Event Table
Display After performing an Auto Event Search, the trace and event table are simultaneously displayed on the screen. Alternatively, you can choose to display just a trace or event table on the screen. In the event table, symbols enable you to identify the types of events.
Auto Mode Measurement
Display5 By combining Auto Set and Auto Save functions, you carry out a
chain of processes automatically such as the following:Automatically detects the conditions of the
fiber being measured and automatically sets
the optimum measurement condition.Starts measuring the average automatically
when the measurement conditions are set.Automatically detects the reflection values,
positioning (distance) and the loss incurred
when the threshold value exceeds the preset
values.Stores the measurement results
automatically Into the specified memory.
Trace Fix Function
Display2 Can quickly and easily compare traces with
the trace fix function. This is a convenient
function to observe the characteristic differences
in multi-core fibers by core, and quickly
check where the core was bended, and the
loss characteristics.
Trace Fix Function
Display3
Multi Wavelength Continuous Measurement is a
function that allows you to switch the wavelength
being measured while keeping the same
measurement conditions. This is convenient
when you need to measure two wavelengths in a
single fiber.
AQ7932 OTDR Emulation software (option)
Display4
The AQ7932 OTDR Emulation Software can be used to create and edit waveform analyses and reports (total tables and waveform
graphs) based on data acquired by the AQ7260 OTDR. And this software can be run on a Windows-based PC.AQ7932 supports the AQ7260 (TRD) and Telcordia (SOR)
formats.
You can check file information before opening the file by the
Preview Function.
With the output layout display, you can check the contents of
reports as you create them.

|||||||| Click here for Detailed Specifications

Display
Display 8.4 inch color TFT (640 480 dots)
Horizontal axis
Full-scale 25m, 50m, 100m, 250m, 500m, 1km, 2km, 2.5km, 5km, 10km, 20km, 40km, 80km, 160km, 240km, 320km, 640km (depend on the optical unit)
Shift 0 to distance range
Readout resolution min. 1cm
Sample data count max. 60,000 points
Group refractive index setting 1.00000 to 1.99999 in 0.00001 steps
Distance measurement Displays the relative one-way distance between any two given points, in eight digits
Vertical axis
Scale 0.2dB/div, 0.5dB/div, 1dB/div, 2dB/div, 5dB/div, 7.5dB/div
Shift 0 to 68dB
Read Resolution Min 0.001dB
Loss measuremen Displays one-way losses in steps of 0.001dB to a maximum of 5 digits
Loss measurement Displays the relative one-way loss, loss per unit length, and splice loss between any two given points on the waveform.
Return-loss measurement function Return loss at mechanical connectors can be measuredTotal return loss of a fiber cable or between any two points can be measured
Memory
Internal Memory 20MB
PCMCIA For stored measurement waveforms and measurement conditions. (A PCMCIA memory card be purchased separately.)
Interface
USB (Host Interface) 2 ports, conforms to USB Rev. 1.0, USB memory (Supports memory without security functions.), keyboard, printer
Printer / FDD Can mount cable less on the back of the optical module cover. (Must purchase an optional unit separately.)
Power Requierments
AC Adapter AC100 to 240V, max. 60W (When using optional printer unit during charging battery)
Battery Li-Ion, Operating time : approx. 6 hours (measurement for 30 seconds in every 3 minutes, using AQ7261 without any optional units, in Power Save Mode)charging time : < 5 hours (Room temperature is 23 °C when the power is OFF.)
Environmental
Operating Temperature -10 to +50°C (During charging : +5 to +35°C)
Storage Temperature -20 to +60°C
Relative humidity 95% or less (no condensation)
Dimensions
Dimensions Approx. 299 (W) 225 (H) 62 (D) mm (Has no projections)
Weight Approx. 3kg (Included optical modules. The weight is 3.3kg when AQ7269 is mounted.)

|||||||| Click here for Detailed Module Specifications

Optical Modules–(AQ7261 SMF
AQ7264 SMF and
AQ7265 SMF)
Optical modules AQ7261 SMF AQ7264 SMF AQ7265 SMF
Measured wavelength (nm) 1310/1550 +/-25
1310/1550 +/- 20
Measured fiber
SM (ITU-T G.652)
Distance range (km)
2, 5, 10, 20, 40, 80, 160, 240, 320, 640 6)
Pulse width (sec) 5)
10n, 20n, 50n, 100n, 200n, 500n, 1μ, 4μ, 10μ, 20μ,50μ 3)
Distance sampling resolution
min. 5cm
Distance sampling points
max. 60,000 points
Distance
Measurement
Accuracy (m)
Optical modules AQ7261 SMF AQ7264 SMF AQ7265 SMF
Offset error
± 1m
Scale error
± 1 sampling resolution
Sampling error
Measured distance 2 10-5
Dead Zone (m)
Optical modules AQ7261 SMF AQ7264 SMF AQ7265 SMF
Event 1) 2 typ. 2 typ. 2 typ.
Attenuation 2) 15/20 typ. 7/8 typ. 7/8 typ.
Optical modules AQ7261 SMF AQ7264 SMF AQ7265 SMF
Dynamic range (dB) SNR=1, for 3 minutes 34/32 9)35/33 typ. 40/38 9)42/40 typ. 43/41 9)45/43 typ.
Loss Measurement Accuracy
Stabilized Light
Source
Optical modules AQ7261 SMF AQ7264 SMF AQ7265 SMF
Wavelength (nm) NA 1310/1550 1310/1550
Max. output (dBm) NA -3 ±2 -3 ±2
Stability (dB) 4) NA ± 0.1 ± 0.1
Optical connector
Environmental
condition
Optical modules AQ7261 SMF AQ7264 SMF AQ7265 SMF
Operating Temperature
-10 to +50°C
Storage Temperature
-20 to +60°C
Humidity
95% or less (no condensation)
  1. Distance width between the event peak point, where the return loss is 40 dB or higher (event is not
    saturated), and the point where the level is 1.5 dB smaller than the event peak.
    At pulse width 10ns.
  2. Distance width at points where the optical connector’s return loss is 45 dB or higher and the back
    scatter level is within +/- 0.5 dB of the normal level. At pulse width 10ns.
  3. 50μs is only 1550nm of AQ7264/AQ7265.
  4. 5minutes measurement at constant temperature.
  5. 1μs can be set at a distance range of over 10km, and 4μs can be set at a distance range of over
    40km.
  6. When measuring 1310nm, the maximum is 320km. When measuring 1550nm, the maximum is
    640km. (AQ7264/AQ7265 only)
  7. 40km, 80km is only 1300nm.
  8. 500ns, 1μs is only 1300nm.
  9. At pulse width 20μs and filter ON.
  10. At GI 62.5/125μm
  11. Distance width at points where the optical connector’s return loss is 40 dB or higher and the back
    scatter level is within +/- 0.5 dB of the normal level. At pulse width 10ns.
  12. At pulse width 200ns (850nm), 1μs (1300nm) and filter ON.
  13. For AQ7269 MMF at 62.5/125μm
  14. mark is connector type. Selectable connector type. (FC, SC, ST, DIN)

 

Optical Modules–(AQ7269 MMF/SMF)
Optical modules
AQ7269 MMF/SMF
Measured wavelength (nm) 850/1300 +/- 30 1310/1550 +/-25
Measured fiber GI (62.5/125μ, 50/125μ) SM (ITU-T G.652)
Distance range (km) 1, 2, 5, 10, 20, 40, 80 7) 2, 5, 10, 20, 40, 80, 160, 240
Pulse width (sec) 5) 10n, 20n, 50n, 100n,
200n, 500n, 1μ8)
10n, 20n, 50n, 100n, 200n,
500n, 1μ, 4μ, 10μ, 20μ
Distance sampling resolution min. 5cm
Distance sampling points max. 60,000 points
Distance
Measurement
Accuracy (m)
Optical modules
AQ7269 MMF/SMF
Offset error
± 1m
Scale error
± 1 sampling resolution
Sampling error
Measured distance 2 10-5
Dead Zone (m)
Optical modules
AQ7269 MMF/SMF
Event 1) 2 typ. 10) 2 typ.
Attenuation 2) 7/8 typ. 7/8 typ.
Optical modules
AQ7269 MMF/SMF
Dynamic range (dB) SNR=1, for 3 minutes 22.5/24 10) 12) 34/32 9)
Loss Measurement Accuracy
Stabilized Light
Source
Optical modules
AQ7269 MMF/SMF
Wavelength (nm) NA NA
Max. output (dBm) NA NA
Stability (dB) 4) NA NA
Optical connector
Environmental
condition
Optical modules
AQ7269 MMF/SMF
Operating Temperature
0 to +40°C
Storage Temperature
-20 to +60°C
Humidity
95% or less (no condensation)
  1. Distance width between the event peak point, where the return loss is 40 dB or higher (event is not
    saturated), and the point where the level is 1.5 dB smaller than the event peak.
    At pulse width 10ns.
  2. Distance width at points where the optical connector’s return loss is 45 dB or higher and the back
    scatter level is within +/- 0.5 dB of the normal level. At pulse width 10ns.
  3. 50μs is only 1550nm of AQ7264/AQ7265.
  4. 5minutes measurement at constant temperature.
  5. 1μs can be set at a distance range of over 10km, and 4μs can be set at a distance range of over
    40km.
  6. When measuring 1310nm, the maximum is 320km. When measuring 1550nm, the maximum is
    640km. (AQ7264/AQ7265 only)
  7. 40km, 80km is only 1300nm.
  8. 500ns, 1μs is only 1300nm.
  9. At pulse width 20μs and filter ON.
  10. At GI 62.5/125μm
  11. Distance width at points where the optical connector’s return loss is 40 dB or higher and the back
    scatter level is within +/- 0.5 dB of the normal level. At pulse width 10ns.
  12. At pulse width 200ns (850nm), 1μs (1300nm) and filter ON.
  13. For AQ7269 MMF at 62.5/125μm
  14. mark is connector type. Selectable connector type. (FC, SC, ST, DIN)

  • Related Products
  • Product Categories
  • AQ7260 Modules

  • Digital transmission test instruments10 Gbit/s BERT module, E/O modules, O/E modules
  • Optical sourcesLD light sources, Fabry-Perot LD modules, DFB-LD module, Tunable laser source module, White light source
  • Optical power metersOptical powermeters, Sensor modules, Sensor heads, High resolution reflect meter for return loss measurement
  • OTDR
  • Optical time domain reflectometers
  • Optical spectrum analysis products
  • Optical spectrum analyzers
  • Display testerDisplay tester for luminance, contrast, flicker and chromaticity measurements.
  • Optical attenuators, switches and othersOptical attenuators, Optical attenuator modules, Optical switch
  • PlatformsMulti-application Test system
  • Optical sensing productsFBG sensor monitor, Optical fiber strain analyzer
  • Optical Transport AnalyzersMeasure the
    transmission and reception of communication frames, alarm/error characteristics,
    and the transmission characteristics

Model Center wavelength Measured fiber Dead zone (m) Dinamic range
(Spec) (nm) Event Atten. (dB)
AQ7261 1310/1550?25 SM (ITU-T G.652) 2 (typ) 15/20 (typ) 34/32 35/33 (typ)
AQ7264 1310/1550?20 SM (ITU-T G.652) 2 (typ) 7/8 (typ) 40/38 42/40 (typ)
AQ7265 1310/1550?20 SM (ITU-T G.652) 2 (typ) 7/8 (typ) 43/4145/43(typ)
AQ7269 MMF 850/1300?30 GI (50/125?m)GI (625/125?m) 2 (typ) 7/10 (typ) 22.5/24
SMF 1310/1550?25 SM (ITU-T G.652) 2 (typ) 7/8 (typ) 34/32

space
pdf_pic Downloads: Specifications
base

 

 

index mail


web