Product Specifications:

space
  • Pulse generator and meter:
    Wide setting range of 0.1 Hz to 11k Hz. A simple key action switched over the function between a pulse generator and pulse meter, suitable for checking flowmeters and receiver instruments.
  • Both voltage pulses and contact pulses are available:
    The CA13 can generate and measure both voltage pulses (amplitude of +0.1 to +15V, zero-based waveform) and contact pulses.
  • Duty ratio setting key:
    The duty ratio of the generated pulses can be set in increments of 10% (Within the range of 10 to 90% except for the two-phase output).
  • Display switching key:
    Switches over the display between the frequency setting, amplitude setting and number-of-pulse setting (when using a PULSE CYCLES range).
  • Plug for input and two-phase output:
    The leftmost input plug can be used as an additional output terminal only by setting an internal dip switch for two-phase output.
  • Generation of DC voltage and current:
    A DC voltage (0.1 to 15V) and current (step setting of 4↔8↔12↔16↔20 mA) can be generated. (Note that the accuracy is ±0.5% of full scale. Use this function only for simplified checks. For precise measurement, use the CA11.)
  • Pulse cycle output:
    A set number of pulses (of a desired frequency and amplitude) can be output, ideal for checking totalizer counters.
  • CPM function:
    The CA13 can count the number of pulses per minute when using the measurement function, suitable for totalizing the flow rate based on discontinuous pulses from a flowmeter. When using the generation function, the pulse train signal to be output can be set by a number of pulses per minute (60 CPM=1 Hz).

Pulse Generation:

space
Range
Range of Generated Signal
Accuracy
Resolution
10kHz
-0.9 to 11.0 kHz ±0.1 kHz
±0.1 kHz 0.1 kHz
1kHz 90 to 1,100 Hz ± 1 Hz 1 Hz
100Hz 1.0 to 110.0 Hz ± 0.1 Hz 0.1 Hz
10000 CPM ±10 CPM 10 CPM
_____
Pulse Cycles 10kHz 10 to 11,000 cycles

_____
1kHz
100Hz
space
DC Voltage / Current :
space
Range
Generated Signal
Accuracy
Resolution
10V 0.0 to +15.0 V DC ±0.5% of full scale 0.1 V
4-20mA 4/8/12/16/20 mA DC ±0.5% of full scale 4 mA
space

Measurement Functions :

space
Range
Range of Generated Signal
Accuracy
Resolution
10kHz
0.001 to 11.000 kHz
±2 digits 0.001 kHz
1kHz 1.0 to 1100.0 Hz ±2 digits 0.1 Hz
100Hz 1.00 to 110.00 Hz ±2 digits 0.01 Hz
10000 CPM 10 to 11,000 cycles

–––––
1 CPM