Features
- Accuracy 0.5% at DC voltage and 4300 count digital Display
- Compact size & ideal for carrying
- Large display for easy viewing
- Safe design allows measurement in excess of 20A
- Auto hold function
- 3 year warranty
Measurement Functions
- DC Voltage • AC voltage • DC current • AC current • Resistance • Continuity check • Diode test • Auto hold • Overvoltage and current warning
Description
The Yokogawa 732 Series Digital Multimeter is a 3.5-digit, 4,300-count Mean Value Type meter. The 732 Series multimeter measures Voltage, Current, Resistance, Continuity Check, Diode Test, Frequency, and Capacitance. Yokogawa’s DMMs provides you with a quality product to meet all your expectations.
- Literature
- Specifications
Model: Yokogawa 73201 DMMs
|
Display |
Digital display: |
4300-count digital reading |
DC Voltage Measurement |
Range |
Accuracy |
Input Resistance |
Max. Voltage |
400.0 mV |
0.5% + 1 ct |
>100 MΩ |
600 V |
4.000 V |
11MΩ |
40.00 V |
0.75% + 1ct |
10MΩ |
400.0 V |
600 V |
AC Voltage Measurement [RMS] (~V) |
Range |
Accuracy |
Impedance |
Max. Voltage |
4.000 V |
1% + 5 cts |
>11 MΩ, <50 pF |
600 Vrms |
40.00 V |
400.0 V |
>10MΩ<50pF |
600V |
DC Current Measurement (A) |
Range |
Accuracy |
Voltage Drop |
Max. Current |
400.0 µA |
1% + 2 cts |
<0.17 mV/µA |
400 mA
(500 mA/600 V fuse-protected) |
4000 µA |
40.00 mA |
<3 mV/mA |
400.0 mA |
4.000 A |
2% + 2 cts |
<0.04 V/A |
10A
fuse-protected |
10A |
AC Current Measurement (~A) |
Range |
Accuracy |
Voltage Drop |
Max. Current |
400.0 µA |
2% + 20 cts |
<0.17 mV/µA |
400 mA
(500 mA/600 V fuse-protected) |
4000 µA |
2% + 5 cts |
40.00 mA |
2% + 20 cts |
<4mV/mA |
400.0 mA |
2% + 5 cts |
4.000 A |
2.5% + 20 cts |
<0.1V/A |
10A
fuse-protected |
10A |
Resistance Measurement (Ω) |
Range |
Accuracy |
Max Test Current |
Protection Voltage |
400.0 Ω |
0.75% + 2 cts |
<1 mA |
600 V |
4.000 kΩ |
0.75% + 1 ct |
<0.5 mA |
40.00 kΩ |
<70 µA |
400.0 kΩ |
<7 µA |
4.000 MΩ |
2% + 1 ct |
<0.7 µA |
40.00 MΩ |
5% + 2 cts |
<70 µA |
Continuity Check |
Range |
Continuity Beeper |
Open-circuit Voltage |
Protection Voltage |
400.0 Ω |
sounds at 50 ± 20 Ω or less |
<3.4 V |
600 V |
Diode Test |
Range |
Accuracy |
Open-circuit Voltage |
Protection Voltage |
2.00 V |
1% + 1 ct 1( mA or less) |
<3.4 V |
600 V |
****See specification sheet for full specifications***** |
General specifications |
Measure Rate: |
Approx. 2 times/sec between input terminals and casing |
Power Supply: |
Two AAA (LR03 or R03) dry cells |
Battery Life: |
Approx. 600 hours
(for continuous DC voltage measurement with alkaline cells) |
Auto Power Off: |
The power is automatically turned off when no operation is made for approx. 20 minutes (can be disabled) |
Withstanding Voltage: |
3.7 kV AC for 1 minute
between input terminals and casing |
Dimensions: |
:74 (W) x 155 (H) x 31 (D) mm |
Weight: |
Approx. 240 g (including batteries) |
Environment |
Operating Temp.: |
-0 to 50˚C; 80% RH or less at 0˚C to 40˚C, or 70% RH or less at 40˚C to 50˚C (no condensation) |
Storage Temp: |
-20˚C to 60˚C, 70 RH or less (no condensation) |
Temperature Coeff.: |
Add accuracy x 0.1/ ˚C to the basic accuracy at a temperature within 0˚C to 18˚C and 28˚C to 50˚C |
Compliance Standards: |
Safety EN61010-1, EN61010-2-030, EN61010-031, 1000V CAT#, 600V CAT$, pollution level 2
UL 61010-1, CAN/CSA-C22.2 No. 61010-1
UL 61010-031, CAN/CSA-C22.2 No. 61010-031 |
|