Features
- High Precision
- Basic accuracy 0.09%
- True RMS measurement
- Ensured Field Site Safety
- Safety shutters preventing erroneous insertion of leads
- New Functions for Yokogawa Middle Class DMMs
- Current direct reading function
clamp sensor (optional)
- Low-pass Filter (LPF)
- Logging-mode memory for 1600 data
- USB communication (Optional communication package)
- Closed Case Calibration
Measurement Functions
- DC Voltage • AC voltage • DC current • AC current • Resistance • Frequency • Temperature • Capacitance • Continuity check • Diode test For AC voltage/current • Low-pass filter can be switched on/off • Data hold/auto hold/range hold • Relative and percentage value calculation • Auto power off
Description
Yokogawa’s TY520 Digital Multimeter is a 3.5-digit (6000-count dual display, 31-segment bar graph display), RMS type meter. The TY520 measurement Functions are: Voltage, Current, Resistance, Continuity Check, Diode Test, Frequency, Capacitance, and Temperature. Basic features of the TY520 include: Category IV 600V, Category III 1000V, USB Communication function, Closed Case Calibration (User calibration function).
- Literature
- Measurement Functions
- Specifications
Full Support for Data Management
Real-time measurement
The optional communication package sold separately (Model 92015) allows you to connect to a PC for transmitting large amounts of data that cannot be saved in the DMM internal memory.
You can transmit the saved data from the internal memory to a PC and process it using application software or spreadsheet software (Excel) for data management.
Measurement Functions
Direct reading of various sensor output signals
The DMM can directly read the various sensor output signals (mV DC/AC) at any scaling. The units can be changed (16 units are available).
Output signal and scaled value are simultaneously displayed.
Closed Case Calibration
User calibration function
The TY series, simply performing special operations via front panel allows for quick and reliable adjustment. In addition, the series allows for one-touch adjustment of AC voltage- and AC current-to-frequency characteristics. The user calibration function leads to improved operation efficiency and cost reduction.
Safe Design
Conforms to EN61010-1 safety standard
Conforms to measurement category 1000 V AC/DC, CAT Ⅲ and 600 V
AC/DC, CAT Ⅳ
Shutters prevent erroneous insertion of test leads into current measurement terminals (terminal shutters)
The current terminals have terminal shutters that prevent erroneous setting of the measurement function and lead wire connections resulting from operational errors. The terminal shutters open and close according to the function switch position.
Model: Yokogawa TY520 DMMs
|
Display |
4-digit LCD: |
7-segment |
Digital display: |
[6,000] counts |
Bar graph display: |
31-segment |
Polarity indicator: |
“-” appears automatically when the polarity is negative |
Overrange indicator: |
“OL” |
DC Voltage Measurement |
Range |
Res. |
Accuracy |
Resistance |
Max. Voltage |
600mV |
0.1mV |
0.09% +2 cts |
10MΩ |
1000V DC
1000V rms AC |
6V |
0.001V |
11MΩ |
60V |
0.01V |
10MΩ |
600V |
0.1V |
1000V |
1V |
0.15% +2 cts |
AC Voltage Measurement [RMS] (~V) |
Range |
Res. |
Accuracy |
Impedance |
Max. Voltage |
600mV |
0.1mV |
0.5% + 5 cts – 60 Hz
0.5% + 5 cts – 4-500 Hz
1.5% + 5 cts – 500 – 1kHz |
10MΩ, <200pF |
1000V DC
1000V rms AC |
6V |
0.001V |
11MΩ, <50pF |
60V |
0.01V |
10MΩ<50pF |
600V |
0.1V |
1000V |
1V |
DC Current Measurement (A) |
Range |
Res. |
Accuracy |
Resistance |
Max. Current |
600µA |
0.1µA |
0.2%+2 cts |
<0.12mV/µA |
440mA
fuse-protected |
6000µA |
1µA |
60mA |
0.01mA |
<3.3mV/mA |
600mA |
0.1mA |
6A |
0.0001A |
0.2%+5 cts |
<0.1V/A |
10A
fuse-protected |
10A |
0.001A |
AC Current Measurement (~A) |
Range |
Res. |
Accuracy |
Resistance |
Max. Voltage |
500µA |
0.01µA |
1 to 1.5%+20 cts |
<0.11mV/µA |
440mA
fuse-protected |
5000µA |
0.1µA |
50mA |
0.001mA |
<4mV/mA |
500mA |
0.01mA |
5A |
0.0001A |
1% to 2%+20 cts |
<0.1V/A |
10A
fuse-protected |
10A |
0.001A |
Resistance Measurement (Ω) |
Range |
Res. |
Accuracy |
Max Test Current |
Protection Voltage |
600Ω |
0.1Ω |
0.4% + 1 cts |
<3.5mA |
1000V rms |
6kΩ |
0.001kΩ |
<0.13µA |
60kΩ |
0.01kΩ |
600kΩ |
0.1kΩ |
6MΩ |
0.001MΩ |
0.5% + 1 cts |
60MΩ |
0.01MΩ |
1% + 2 cts (0-40MΩ)
2% + 2 cts (40-60MΩ) |
Frequency Measurement (Hz) |
Range |
Res. |
Accuracy |
input Voltage |
|
10.00 – 99.99Hz |
0.01Hz |
0.02%+1 cts |
0.2 – 600V rms |
90.0 – 999.9Hz |
0.1Hz |
0.900 – 9.999Hz |
0.001kHz |
0.4 – 600V rms |
9.00 – 99.99kHz |
0.01kHz |
0.8 – 100V rms |
Capacitance |
Range |
Res. |
Accuracy |
input Voltage |
|
10nF |
0.01nF |
2%+10 cts |
1000V rms |
100nF |
0.1nF |
2%+5 cts |
1µF |
0.001µF |
10µF |
0.01µF |
100µF |
0.1µF |
3%+5 cts |
1000 µF |
µ1F |
Temperature Measurement (TEMP) |
Range |
Res. |
Accuracy |
Input Voltage |
|
-50 – 600°C |
0.1°C |
1 to 1.5%+20 cts |
1000V rms |
****See specification sheet for full specifications***** |
General specifications |
Measuring Rate: |
:5 times/sec (Frequency: 1 time/sec, Capacitance: max. 0.14 times/sec (1000µF), Resistance: 2.5 times/sec, Temperature: 0.7 times/sec)
Bar graph display: 25 times/sec (DC voltage, diode test: 5 times/sec) |
Power Supply: |
Four AA (R6) dry cells |
Battery Life: |
Approx. 300 hours (for continuous DC voltage measurement with alkaline cells) |
Withstanding Voltage: |
6.88kV for 5 seconds (between input terminals and casing) |
Dimensions: |
Approx. 90(W) x 192(H) x 49(D) mm |
Weight: |
Approx. 570g (including batteries) |
Environment |
Operating Temp.: |
-10 to 55°C; 80% RH or less (no condensation) 40 to 55°C; 70% RH or less |
Storage Temp: |
-30 to 70°C; 70% RH or less (no condensation) |
Temperature Coeff.: |
Add the accuracy 0.1/°C to the basic accuracy at a temperature within -10 to 18°C and 28 to 55°C. |
Compliance Standards: |
Safety EN61010-1, EN61010-2-030, EN61010-031, 1000V CAT#, 600V CAT$, pollution level 2
UL 61010-1, CAN/CSA-C22.2 No. 61010-1
UL 61010-031, CAN/CSA-C22.2 No. 61010-031 |
|